Wilo DL-E 100/145-11/2-S1 Dry-running twin pump
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Iisdpfx Aswbqrtekgjh
Configuration of all operating parameters
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Iisdpfx Aswbqrtekgjh
Configuration of all operating parameters
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
登録日: 2008
534 オンライン広告
お問い合わせを送信
電話 & ファックス
+49 2862 ... 広告
これらの広告もご興味があるかもしれません。
成功
あなたのメッセージが送信されました。
小型広告
Framrach
9,216 km
コンベヤー
ASCOCB 3000 - 2023
ASCOCB 3000 - 2023
成功
あなたのメッセージが送信されました。
小型広告
Frankenberg/Sa.
8,961 km
エタノームG 150-250ポンプ
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
成功
あなたのメッセージが送信されました。
小型広告
Thisted
8,636 km
グルンドフォス・ポンプ
GrundfosCR 8-30
GrundfosCR 8-30
成功
あなたのメッセージが送信されました。
小型広告
Leipzig
8,951 km
ラインモーター
Leomotor A/SKC 218B159 - LM 2000 - 12630
Leomotor A/SKC 218B159 - LM 2000 - 12630
成功
あなたのメッセージが送信されました。
小型広告
Luckenwalde
8,858 km
バー搬送コンベヤシステム
PROTONBar Transferred Conveyor
PROTONBar Transferred Conveyor
成功
あなたのメッセージが送信されました。
小型広告
Nordhorn
9,093 km
ベルトコンベア
Caljan
Caljan
成功
あなたのメッセージが送信されました。
小型広告
Topole
8,527 km
ローラーコンベア
RegaluxEPRIS760-10000
RegaluxEPRIS760-10000
成功
あなたのメッセージが送信されました。
小型広告
Topole
8,527 km
傾斜ベルトコンベヤ
VanderlandeZ-Förderer
VanderlandeZ-Förderer
成功
あなたのメッセージが送信されました。
小型広告
Piskorzów
8,762 km
電気モーター 210Kw
LoherANSA 315LB-04C
LoherANSA 315LB-04C
成功
あなたのメッセージが送信されました。
小型広告
Krotoszyn
8,686 km
ポンプユニット/油圧ポンプ
DP PumpsHU 4 UL DPV15/4 SVP NW100 R L LEFT
DP PumpsHU 4 UL DPV15/4 SVP NW100 R L LEFT
あなたの掲載は正常に削除されました
エラーが発生しました