恒温恒湿試験器 +20~+130℃ 240リットルWeiss Technik
EmissionEvent VOC/240
恒温恒湿試験器 +20~+130℃ 240リットル
Weiss Technik
EmissionEvent VOC/240
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A21172407
- リファレンス番号:
- 25033
- 更新:
- 最終更新日:05.02.2026
説明
Weiss
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
Bodpfxeyhfg Ds Ab Tewh
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
Bodpfxeyhfg Ds Ab Tewh
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
あなたの掲載は正常に削除されました
エラーが発生しました