恒温チャンバーVötsch
VTS 7011-5
恒温チャンバー
Vötsch
VTS 7011-5
状態
中古
所在地
Borken 

機械に関するデータ
価格と所在地
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A22215042
- リファレンス番号:
- 24319
- 更新:
- 最終更新日:26.06.2026
説明
Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: width 560 mm, depth 350 mm, height 630 mm
External dimensions: width 850 mm, depth 1030 mm, height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.3 to 1 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate (cooling): 6 K/min
Njdpfx Aezg Tpcjblecu
Temperature change rate (heating): 10 K/min
Refrigerant: R-404 A / R 23
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 7.5 kW
Rated current: 13 A
Weight: 360 kg
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by telephone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: VTS 7011-5
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: width 560 mm, depth 350 mm, height 630 mm
External dimensions: width 850 mm, depth 1030 mm, height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.3 to 1 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate (cooling): 6 K/min
Njdpfx Aezg Tpcjblecu
Temperature change rate (heating): 10 K/min
Refrigerant: R-404 A / R 23
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 7.5 kW
Rated current: 13 A
Weight: 360 kg
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by telephone.