温度試験室 600リットルCTS
T-70/600 -70°C bis 180°C
温度試験室 600リットル
CTS
T-70/600 -70°C bis 180°C
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A21152047
- リファレンス番号:
- 24458
- 更新:
- 最終更新日:03.02.2026
説明
CTS Climate Test Chamber T-70/600 Water-Cooled
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Load capacity per shelf max. 35 kg
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
Bcodpfxeygulto Ah Tsu
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Load capacity per shelf max. 35 kg
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
Bcodpfxeygulto Ah Tsu
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
これらの広告もご興味があるかもしれません。
小型広告
Borken
9,154 km
温度試験室 600リットル
CTST-70/600/S 70°C bis 180°C
CTST-70/600/S 70°C bis 180°C
小型広告
Borken
9,154 km
温度試験室 600リットル
CTST-70/600/S -70°C bis 180°C
CTST-70/600/S -70°C bis 180°C
あなたの掲載は正常に削除されました
エラーが発生しました