防爆型温度試験キャビネットCTS
T-30/950 Ex/I
防爆型温度試験キャビネット
CTS
T-30/950 Ex/I
製造年
2011
状態
中古
所在地
Borken 

機械に関するデータ
価格と所在地
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A22147762
- リファレンス番号:
- 23117
- 更新:
- 最終更新日:18.06.2026
説明
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
Nedpfx Ajzd Rzweblecu
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
Nedpfx Ajzd Rzweblecu
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level: