CTS Climate Chamber, Climate Testing Cell
Here we offer a CTS climate chamber, climate testing cell.
Available from mid-January 2023!
Water-cooled
Height adjustable!
Footprint approx. (W x D x H): 3755 x 3470 x 2480
Test chamber approx. (W x D x H): 2500 x 2720 x 2200
Test chamber volume: approx. 15 m³
Temperature range: -40°C to +140°C
Temperature deviation 1 K over time
Average temperature change rate without heat radiation, measured in the supply air
Heating: 2 K/min
Cooling: 1 K/min
from +110 °C to -35 °C
Climate tests:
Temperature range: +10 °C to +90 °C
Humidity range: +30% to +95% RH
in the dew point range: +5°C to 89°C
Temperature deviation 0.5 K over time
Humidity deviation ±1 to ±3% RH over time
Rated voltage: 400V 3/N, PE, 50 Hz
Rated power: 53.5 KW
Rated current: 92.3 A
Compressor: S6J-16.2
+ Chilled water unit
Refrigerant: R404A
Weight: 5500 kg
Type: CW-40/16
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
Tedpfxszd R A Uj Acdsc
We will be happy to answer any further questions you may have by telephone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Here we offer a CTS climate chamber, climate testing cell.
Available from mid-January 2023!
Water-cooled
Height adjustable!
Footprint approx. (W x D x H): 3755 x 3470 x 2480
Test chamber approx. (W x D x H): 2500 x 2720 x 2200
Test chamber volume: approx. 15 m³
Temperature range: -40°C to +140°C
Temperature deviation 1 K over time
Average temperature change rate without heat radiation, measured in the supply air
Heating: 2 K/min
Cooling: 1 K/min
from +110 °C to -35 °C
Climate tests:
Temperature range: +10 °C to +90 °C
Humidity range: +30% to +95% RH
in the dew point range: +5°C to 89°C
Temperature deviation 0.5 K over time
Humidity deviation ±1 to ±3% RH over time
Rated voltage: 400V 3/N, PE, 50 Hz
Rated power: 53.5 KW
Rated current: 92.3 A
Compressor: S6J-16.2
+ Chilled water unit
Refrigerant: R404A
Weight: 5500 kg
Type: CW-40/16
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
Tedpfxszd R A Uj Acdsc
We will be happy to answer any further questions you may have by telephone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
お問い合わせを送信
電話 & ファックス
+49 2861 ... 広告
これらの広告もご興味があるかもしれません。
成功
あなたのメッセージが送信されました。
小型広告
Borken
9,154 km
ウォークイン型温度・湿度試験室
CTS KlimaschrankCW+40/7/7 40–90°C
CTS KlimaschrankCW+40/7/7 40–90°C
成功
あなたのメッセージが送信されました。
小型広告
Borken
9,153 km
-60℃ から +120℃、6000リットル(6m³)
CTS KlimaprüfzelleCW-60/6
CTS KlimaprüfzelleCW-60/6
成功
あなたのメッセージが送信されました。
小型広告
Borken
9,154 km
クライメートチェンバー
TiraTTZ 4008
TiraTTZ 4008
あなたの掲載は正常に削除されました
エラーが発生しました