Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Hedex Hhfhjpfx Agwoi
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Hedex Hhfhjpfx Agwoi
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
これらの広告もご興味があるかもしれません。
小型広告
Borken
9,153 km
温度ショック試験チャンバー -70~220°C
VötschVT 7012 S2
VötschVT 7012 S2
小型広告
ドイツ
8,951 km
溶接システム
KEMPPIPro MIG 500
KEMPPIPro MIG 500
小型広告
Borken
9,154 km
ショックテストチャンバー –80 °C から +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
小型広告
Borken
9,154 km
衝撃試験器 -80℃~+220
VötschVT 7012 S2
VötschVT 7012 S2
小型広告
Concordia Sagittaria
9,400 km
多工程溶接機 500アンペア
GYSNEOMIG -i 500 G
GYSNEOMIG -i 500 G
小型広告
Borken
9,154 km
衝撃試験室 +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
小型広告
Borken
9,154 km
ショックテストチャンバー –80 °C から +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
小型広告
Bünde
9,052 km
三次元測定器
MORAPrimus 686
MORAPrimus 686
小型広告
ドイツ
8,951 km
溶接システム
KEMPPIPro MIG 500
KEMPPIPro MIG 500
小型広告
Balaguer
10,336 km
溶接機
KEMPPIPRO 3000
KEMPPIPRO 3000
あなたの掲載は正常に削除されました
エラーが発生しました