説明
TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Pedpfx Aszh Htqsh Eogu
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the test chamber) ±0.1°C ... ±0.3°C
Maximum temperature change rate
Pedpfx Aszh Htqsh Eogu
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% to ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x W x H) 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf 50 kg
Maximum floor load of the test chamber 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.