Malvern Omnisec CHR600 + CHR7100 Resolve & Reveal GPC/SECシステムMalvern Omnisec
CHR600 + CHR7100
Malvern Omnisec CHR600 + CHR7100 Resolve & Reveal GPC/SECシステム
Malvern Omnisec
CHR600 + CHR7100
状態
中古
所在地
Duxford 

機械に関するデータ
価格と所在地
- 所在地:
- Duxford, UK

電話する
オファーの詳細
- 広告ID:
- A21043862
- リファレンス番号:
- 1525.2A
- 更新:
- 最終更新日:22.01.2026
説明
This listing is for the Malvern CHR6000 + CHR7100 OMNISEC RESOLVE and REVEAL GPC/SEC
These units are in full working condition and ready for immediate use
What the System Measures
The combined OMNISEC RESOLVE and REVEAL GPC/SEC System provides absolute molecular weight, intrinsic viscosity, concentration, and conformational data in a single run. This eliminates the need for calibration standards, improving accuracy and confidence in results.
Fsdpfxsychy Aj Ag Aspg
OMNISEC RESOLVE – The Chromatography Module
OMNISEC RESOLVE integrates four key components into a single unit:
Pump: Delivers a flow rate range of 0.01–10 mL/min with low pulsation (0.15% at 1 mL/min in water), ensuring stable baseline signals.
Degasser: Features a low-volume (960 µL) design for rapid solvent exchange, enhancing system productivity.
Autosampler: Accommodates up to 192 samples, with temperature control from 4°C to 60°C, suitable for both vials and 96-well microtiter plates.
Column Oven: Controls temperatures up to 65°C, supporting up to six analytical columns for optimal separation conditions.
This integrated design minimizes baseline noise and enhances measurement sensitivity, particularly for low-concentration or low-molecular-weight samples.
OMNISEC REVEAL – The Detector Module
OMNISEC REVEAL is an advanced, fully integrated, temperature-controlled multi-detector module that includes:
Refractive Index (RI) Detector: Highly sensitive and stable, enabling accurate concentration measurement, even for low-concentration samples.
UV/Vis Photodiode Array (UV-PDA) Detector: Measures absorbance at any wavelength from 190 to 900 nm, providing versatile detection options.
Light Scattering Detectors (LALS & RALS): Deliver market-leading sensitivity, allowing measurement of molecular weights as low as 200 g/mol and injection masses as low as 100 ng, for highly reliable results.
Viscometer: Features automated balancing for precise intrinsic viscosity measurements, with a user-exchangeable capillary bridge to minimize maintenance.
The fully temperature-controlled design improves detector stability and overall sample characterization, ensuring optimal performance for sensitive applications.
OMNISEC Software
The OMNISEC software suite provides:
Unified instrument control, data acquisition, and analysis.
Calculations for molecular weight (Mn, Mw, Mz), polydispersity, radius of gyration (Rg), intrinsic viscosity, and Mark-Houwink parameters.
Support for automated, unattended operation to streamline workflows.
Key Advantages
Exceptional Sensitivity: Measures molecular weights down to 200 g/mol and injection masses as low as 100 ng.
Broad Wavelength UV/Vis Detection: Enables absorbance measurements across 190–900 nm.
Superior Stability: Temperature-controlled detectors ensure consistent, high-quality results.
Versatility: Ideal for polymers, polysaccharides, and proteins, with multi-detection SEC offering unmatched characterization detail.
Integrated Design: Reduced inter-detector volume improves peak resolution and data quality.
Accurate Viscosity Measurement: With automated viscometer balancing, ensuring reproducibility.
These units are in full working condition and ready for immediate use
What the System Measures
The combined OMNISEC RESOLVE and REVEAL GPC/SEC System provides absolute molecular weight, intrinsic viscosity, concentration, and conformational data in a single run. This eliminates the need for calibration standards, improving accuracy and confidence in results.
Fsdpfxsychy Aj Ag Aspg
OMNISEC RESOLVE – The Chromatography Module
OMNISEC RESOLVE integrates four key components into a single unit:
Pump: Delivers a flow rate range of 0.01–10 mL/min with low pulsation (0.15% at 1 mL/min in water), ensuring stable baseline signals.
Degasser: Features a low-volume (960 µL) design for rapid solvent exchange, enhancing system productivity.
Autosampler: Accommodates up to 192 samples, with temperature control from 4°C to 60°C, suitable for both vials and 96-well microtiter plates.
Column Oven: Controls temperatures up to 65°C, supporting up to six analytical columns for optimal separation conditions.
This integrated design minimizes baseline noise and enhances measurement sensitivity, particularly for low-concentration or low-molecular-weight samples.
OMNISEC REVEAL – The Detector Module
OMNISEC REVEAL is an advanced, fully integrated, temperature-controlled multi-detector module that includes:
Refractive Index (RI) Detector: Highly sensitive and stable, enabling accurate concentration measurement, even for low-concentration samples.
UV/Vis Photodiode Array (UV-PDA) Detector: Measures absorbance at any wavelength from 190 to 900 nm, providing versatile detection options.
Light Scattering Detectors (LALS & RALS): Deliver market-leading sensitivity, allowing measurement of molecular weights as low as 200 g/mol and injection masses as low as 100 ng, for highly reliable results.
Viscometer: Features automated balancing for precise intrinsic viscosity measurements, with a user-exchangeable capillary bridge to minimize maintenance.
The fully temperature-controlled design improves detector stability and overall sample characterization, ensuring optimal performance for sensitive applications.
OMNISEC Software
The OMNISEC software suite provides:
Unified instrument control, data acquisition, and analysis.
Calculations for molecular weight (Mn, Mw, Mz), polydispersity, radius of gyration (Rg), intrinsic viscosity, and Mark-Houwink parameters.
Support for automated, unattended operation to streamline workflows.
Key Advantages
Exceptional Sensitivity: Measures molecular weights down to 200 g/mol and injection masses as low as 100 ng.
Broad Wavelength UV/Vis Detection: Enables absorbance measurements across 190–900 nm.
Superior Stability: Temperature-controlled detectors ensure consistent, high-quality results.
Versatility: Ideal for polymers, polysaccharides, and proteins, with multi-detection SEC offering unmatched characterization detail.
Integrated Design: Reduced inter-detector volume improves peak resolution and data quality.
Accurate Viscosity Measurement: With automated viscometer balancing, ensuring reproducibility.
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
登録日: 2019
796 オンライン広告
お問い合わせを送信
電話 & ファックス
+44 20 38... 広告
これらの広告もご興味があるかもしれません。
小型広告
ドイツ
9,058 km
分光光度計
Datacolor800
Datacolor800
小型広告
Soerendonk
9,258 km
非鉄セパレーター/渦電流セパレーター
SteinertNES 100 220 E 5009
SteinertNES 100 220 E 5009
小型広告
Bischofszell
9,430 km
分光光度計
GRETAG MACBETHEFI ES 1000 (eye-one UVcut)
GRETAG MACBETHEFI ES 1000 (eye-one UVcut)
小型広告
Hadımköy
8,814 km
ウルトラソニッククリーニングマシン
INTERSONIKMINISONIC SERIES
INTERSONIKMINISONIC SERIES
小型広告
Soerendonk
9,258 km
非鉄セパレーター/渦電流セパレーター
Bakker Magnetics29.723/12
Bakker Magnetics29.723/12
小型広告
Wekerom
9,179 km
ビッグバッグ排出ステーション
小型広告
Wekerom
9,179 km
ビッグバッグ充填・排出システム(投入ホッパー付)
小型広告
Budapest
8,922 km
ビッグバックサックハルターシステム
nicht bekanntBIG BAG Sack Halter System
nicht bekanntBIG BAG Sack Halter System
小型広告
ドイツ
9,058 km
色彩選別装置
CimbriaN7-D-D
CimbriaN7-D-D
小型広告
Töltéstava
8,992 km
ヒュームフード
BioquellAstec Monair BFC5-002
BioquellAstec Monair BFC5-002
あなたの掲載は正常に削除されました
エラーが発生しました