温度試験チャンバー 600リットルCTS Temperaturprüfschrank
T-40/600 -40°C bis 180°C
温度試験チャンバー 600リットル
CTS Temperaturprüfschrank
T-40/600 -40°C bis 180°C
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A20740542
- リファレンス番号:
- 24921
- 更新:
- 最終更新日:11.12.2025
説明
CTS
Type: T-40/600
Water-cooled Temperature Test Chamber
Control System:
- 32-bit controller
- LCD control panel
- Digital display of set and actual values
- Numeric input for set values
- Error messages in plain text
- RS 232 interface
- Free switching channels for user-specific test item control
Technical Specifications
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 2.5 K/min
Cooling: 2.5 K/min
Heat dissipation:
Approx. 2500 W at +20°C
Approx. 2500 W at 0°C
Approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, no radiation, and without additional equipment.
Dimensions:
Test volume: 600 liters
Test chamber dimensions (H x W x D): approx. 850 mm x 850 mm x 830 mm
External dimensions (H x W x D): approx. 1900 mm x 1120 mm x 1875 mm
Operating Data:
Power connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 7.1 kW
Rated current: 12.3 A
Protection class: IP 22
Weight: approx. 700 kg
Refrigerant: R-452A / R23
Gsdpfx Aox E Tq Tedgoca
For your safety as a buyer, please note the following procedures are performed on all chambers offered:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of supply: (See picture)
(Specifications subject to change and errors excepted!)
For further questions, we are happy to assist you by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: T-40/600
Water-cooled Temperature Test Chamber
Control System:
- 32-bit controller
- LCD control panel
- Digital display of set and actual values
- Numeric input for set values
- Error messages in plain text
- RS 232 interface
- Free switching channels for user-specific test item control
Technical Specifications
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 2.5 K/min
Cooling: 2.5 K/min
Heat dissipation:
Approx. 2500 W at +20°C
Approx. 2500 W at 0°C
Approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, no radiation, and without additional equipment.
Dimensions:
Test volume: 600 liters
Test chamber dimensions (H x W x D): approx. 850 mm x 850 mm x 830 mm
External dimensions (H x W x D): approx. 1900 mm x 1120 mm x 1875 mm
Operating Data:
Power connection: 400 V +6/-10%, 3/N, 50 Hz
Rated power: 7.1 kW
Rated current: 12.3 A
Protection class: IP 22
Weight: approx. 700 kg
Refrigerant: R-452A / R23
Gsdpfx Aox E Tq Tedgoca
For your safety as a buyer, please note the following procedures are performed on all chambers offered:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of supply: (See picture)
(Specifications subject to change and errors excepted!)
For further questions, we are happy to assist you by phone.