ロードバンク 1,200 kWAptis
APS1200
ロードバンク 1,200 kW
Aptis
APS1200
FCA VB 消費税別
€35,000
製造年
2026
状態
中古
(完全に稼働しています)
所在地
Pula 

基本データ
価格と所在地
FCA VB 消費税別
€35,000
- レンタル:
- 可能です
- 所在地:
- Pula, クロアチア

電話する
技術詳細
寸法と重量
総重量:
1,300 kg(キログラム)
全長:
1,800 mm
全幅:
1,470 mm
全高:
2,170 mm
書類および認証
CEマーキング
オファーの詳細
- 広告ID:
- A23348348
- 更新:
- 最終更新日:17.11.2026
説明
For sale or rent: Outdoor resistive load banks (2 units are available) with a rated capacity of 1200 kW at 400 V AC, three-phase with neutral, 50/60 Hz. The unit provides a purely resistive load (power factor 1) and is designed for continuous duty in a weatherproof enclosure, including operation outdoors in rain.
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
Nsdpfx Ahj Akvd Rjasli
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
Nsdpfx Ahj Akvd Rjasli
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
登録日: 2025
1 オンライン広告
お問い合わせを送信
電話 & ファックス
+385 98 2... 広告
あなたの掲載は正常に削除されました
エラーが発生しました