ACS Angelantoni Discovery DM 1200 CES ヘッドライト環境試験装置、Huber Unichiller付きACS Angelantoni
Discovery DM 1200 CES
ACS Angelantoni Discovery DM 1200 CES ヘッドライト環境試験装置、Huber Unichiller付き
ACS Angelantoni
Discovery DM 1200 CES
状態
中古
所在地
Borken 

基本データ
価格と所在地
- 所在地:
- Borken, ドイツ

電話する
オファーの詳細
- 広告ID:
- A23371339
- リファレンス番号:
- 25844
- 更新:
- 最終更新日:23.11.2026
説明
ACS Angelantoni Test Technologies
Discovery 2 x DM 1200 C ES
Headlight climate testing system with coupling chamber
Year of manufacture: 2019 / approx. 5,000 kg
2 test chambers with Huber Unichiller 040T
For sale is a used, coupled climate and temperature testing system for testing vehicle headlights.
System configuration / scope of supply:
2 x ACS Discovery climate test chamber
1 x central coupling / test chamber
1 x associated electrical control cabinet
1 x Huber Unichiller 040T
Connection hoses as shown in the pictures
Technical data – ACS:
Manufacturer: ACS / Angelantoni Test Technologies
Model series: Discovery
Type: 2 x DM 1200 C ES + BOX
Year of manufacture: 2019
Weight: approx. 5,000 kg
Main nameplate: 4,575 kg
Additional nameplate: 1,170 kg (not added)
Usable volume according to drawing: approx. 1 m³ per specified test / coupling unit
Temperature and climate data:
Temperature according to nameplate: -75 to +180 °C
Combined, outside: -40 to +130 °C
Combined, engine side: -40 to +180 °C
Separate operation: -70 to +180 °C
Relative humidity according to nameplate: 10-98 %
Dew point range according to drawing: +4 to +80 °C
Supply / cooling technology:
Total system according to drawing: 400 V / 50 Hz
Installed power according to drawing: 54 kW
Average power: approx. 30 kW
Workshop data: 41 A / approx. 20.86 kW
Max. cooling water consumption: 6 m³/h
ACS refrigerant: R452A / 5.00 kg and R23 / 1.10 kg
Electrical equipment (EB_BOX):
400 V / 3 Ph + N + PE / 50 Hz
Full load current: 9 A / Power: 4 kW
Protection class: IP54 / Tolerance: 10 %
Short-circuit current: 15 kA
Standard: IEC/EN 60204-1
Data applies to EB_BOX.
Huber Unichiller 040T:
Temperature range: -10 to +40 °C
Connection: 400 V / 3~ / 50 Hz
Max. current consumption: 5.0 A
Refrigerant: R507A / 2.20 kg
Dimensions according to system layout:
Width closed: approx. 5,200 mm
Nleds Aliwnspfx Ai Ssi
Width open: up to approx. 8,400 mm
Max. height: approx. 2,460 mm
Condition / workshop inspection:
Used
Heating rate measured: 7.64 K/min
Cooling rate measured: 5.78 K/min
24 V power supply replaced.
Electrical system, fan and R23 refrigerant circuit serviced.
Collection / shipping possible by arrangement.
Subject to changes, errors and prior sale.
We will gladly answer any questions by telephone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Discovery 2 x DM 1200 C ES
Headlight climate testing system with coupling chamber
Year of manufacture: 2019 / approx. 5,000 kg
2 test chambers with Huber Unichiller 040T
For sale is a used, coupled climate and temperature testing system for testing vehicle headlights.
System configuration / scope of supply:
2 x ACS Discovery climate test chamber
1 x central coupling / test chamber
1 x associated electrical control cabinet
1 x Huber Unichiller 040T
Connection hoses as shown in the pictures
Technical data – ACS:
Manufacturer: ACS / Angelantoni Test Technologies
Model series: Discovery
Type: 2 x DM 1200 C ES + BOX
Year of manufacture: 2019
Weight: approx. 5,000 kg
Main nameplate: 4,575 kg
Additional nameplate: 1,170 kg (not added)
Usable volume according to drawing: approx. 1 m³ per specified test / coupling unit
Temperature and climate data:
Temperature according to nameplate: -75 to +180 °C
Combined, outside: -40 to +130 °C
Combined, engine side: -40 to +180 °C
Separate operation: -70 to +180 °C
Relative humidity according to nameplate: 10-98 %
Dew point range according to drawing: +4 to +80 °C
Supply / cooling technology:
Total system according to drawing: 400 V / 50 Hz
Installed power according to drawing: 54 kW
Average power: approx. 30 kW
Workshop data: 41 A / approx. 20.86 kW
Max. cooling water consumption: 6 m³/h
ACS refrigerant: R452A / 5.00 kg and R23 / 1.10 kg
Electrical equipment (EB_BOX):
400 V / 3 Ph + N + PE / 50 Hz
Full load current: 9 A / Power: 4 kW
Protection class: IP54 / Tolerance: 10 %
Short-circuit current: 15 kA
Standard: IEC/EN 60204-1
Data applies to EB_BOX.
Huber Unichiller 040T:
Temperature range: -10 to +40 °C
Connection: 400 V / 3~ / 50 Hz
Max. current consumption: 5.0 A
Refrigerant: R507A / 2.20 kg
Dimensions according to system layout:
Width closed: approx. 5,200 mm
Nleds Aliwnspfx Ai Ssi
Width open: up to approx. 8,400 mm
Max. height: approx. 2,460 mm
Condition / workshop inspection:
Used
Heating rate measured: 7.64 K/min
Cooling rate measured: 5.78 K/min
24 V power supply replaced.
Electrical system, fan and R23 refrigerant circuit serviced.
Collection / shipping possible by arrangement.
Subject to changes, errors and prior sale.
We will gladly answer any questions by telephone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。