Zwick Roell HIT5P Plus ペンデュラム衝撃試験機Zwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
Zwick Roell HIT5P Plus ペンデュラム衝撃試験機
Zwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
製造年
2019
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
- 製造年:
- 2019
- 状態:
- 非常に良い(中古)
- 機能性:
- 完全に稼働しています
価格と所在地
- 所在地:
- Mollenwieske 4a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A19716451
- 更新:
- 最終更新日:13.08.2025
説明
Zwick Roell Pendulum Impact Testing Machine HIT5P Plus incl. TestXpert III software and 2 Charpy pendulums
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Kdjdpfxjw H Andj Afnjw
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Kdjdpfxjw H Andj Afnjw
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
これらの広告もご興味があるかもしれません。
小型広告
Menslage
9,038 km
ALWID Krone HV バキュームフィラー(2018年)
ALWIDVakuumfüller
ALWIDVakuumfüller
小型広告
Wiesbaden
9,252 km
ツインチャンバーオーブン
LINNEHWS-3-Spez.
LINNEHWS-3-Spez.
小型広告
Thisted
8,636 km
バルクフィーダー
ABK SwedenSTR 301
ABK SwedenSTR 301
小型広告
Hanau
9,214 km
ゴム加工機
Alpha TechnologiesGummiprüfgeräte MDR
Alpha TechnologiesGummiprüfgeräte MDR
小型広告
Bremen
8,963 km
吸引ランスとポンプを含む注入システム
SeraR 411 W
SeraR 411 W
小型広告
Sonsbeck
9,197 km
無垢の鋼鉄製のパンチングナイフ
Richard Hess MBV GmbHStanzmesser aus vollem Stahl
Richard Hess MBV GmbHStanzmesser aus vollem Stahl
今すぐ購入
Dresden
8,921 km
コンテナを空にする
NetzschBE-5T/3NDP06
NetzschBE-5T/3NDP06
小型広告
Wiefelstede
8,980 km
チップ取り出しファン
EMK15 kW / 2935 U/min
EMK15 kW / 2935 U/min
小型広告
ドイツ
9,058 km
圧延工場
SchwabenthanPolymix 110 P
SchwabenthanPolymix 110 P
小型広告
Siedlce
8,409 km
集塵
CORMAKSCV8900TC
CORMAKSCV8900TC
あなたの掲載は正常に削除されました
エラーが発生しました