セルハーベストポンプWilson Wolf
Gatherex 80000Z
セルハーベストポンプ
Wilson Wolf
Gatherex 80000Z
EXW 固定価格 消費税別
€2,000
製造年
2021
状態
中古
所在地
Töltéstava 

機械に関するデータ
価格と所在地
EXW 固定価格 消費税別
€2,000
- 所在地:
- 0184/3. Hrsz, 9086 Töltéstava, Hungary

電話する
オファーの詳細
- 広告ID:
- A22794160
- 更新:
- 最終更新日:21.09.2026
説明
The GatheRex™ Cell Harvest Pump is a liquid handling device designed to work with closed system cell culture devices. The GatheRex connects to closed system devices and uses a low pressure forced air mechanism to remove media, concentrate cells and minimize storage and/or downstream processing. An internal air pump pressurizes the system by pumping air through the sterile vent filter on the cell culture device. When pressurized, excess media, or a cell fraction, is forced out of the device through the tubing assembly then into a collection receptacle.
Model 80000Z is designated by black ID tags on the tubing pinch clamps. This version is compatible with large diameter tubing (0.375” OD) for media removal and small diameter tubing (0.160” OD blood transfer bag style) for cell recovery.
Knodpsz Dx Sujfx Ac Asb
ELECTRICAL REQUIREMENTS
1. Input: 100-240VAC, ~1.3A, 50-60Hz, Single Phase
Fuse Type: 5ET 3.15-R, Cartridge, Time Delay, 3.15A, 250 V, 5mm x 20mm (0.2” x 0.79”), 5ET Series
Detachable Power Cord: C13, 18AWG, 10A minimum, Grounded (3 Prong), UL 62, CSA-C22.2 No. 49
IEC / UL: 61010-1 edition 3.1 and 61326-1:2012
LOW PRESSURE OUTPUT
1. Gauge Pressure: 120 – 180 mmHg (2.32 – 3.48 psi) No adjustments for altitude are needed.
2. Flow Rate: Minimum 5 mL/sec fluid transfer rate from G-Rex M-CS
ENVIRONMENTAL CONDITIONS
1. Temperature: 15°C to 35°C (59-95°F)
2. Humidity: ≤ 95% Relative Humidity
3. Altitude: < 2,000 meters (6,561 feet)
Good working condition. Please check out our other listings as well.
Model 80000Z is designated by black ID tags on the tubing pinch clamps. This version is compatible with large diameter tubing (0.375” OD) for media removal and small diameter tubing (0.160” OD blood transfer bag style) for cell recovery.
Knodpsz Dx Sujfx Ac Asb
ELECTRICAL REQUIREMENTS
1. Input: 100-240VAC, ~1.3A, 50-60Hz, Single Phase
Fuse Type: 5ET 3.15-R, Cartridge, Time Delay, 3.15A, 250 V, 5mm x 20mm (0.2” x 0.79”), 5ET Series
Detachable Power Cord: C13, 18AWG, 10A minimum, Grounded (3 Prong), UL 62, CSA-C22.2 No. 49
IEC / UL: 61010-1 edition 3.1 and 61326-1:2012
LOW PRESSURE OUTPUT
1. Gauge Pressure: 120 – 180 mmHg (2.32 – 3.48 psi) No adjustments for altitude are needed.
2. Flow Rate: Minimum 5 mL/sec fluid transfer rate from G-Rex M-CS
ENVIRONMENTAL CONDITIONS
1. Temperature: 15°C to 35°C (59-95°F)
2. Humidity: ≤ 95% Relative Humidity
3. Altitude: < 2,000 meters (6,561 feet)
Good working condition. Please check out our other listings as well.