Heraeus shock test chamber +50°C to +220°C, -65°C to +70°C, HT 7012 S2Vötsch
Heraeus Schocktestkammer
Heraeus shock test chamber +50°C to +220°C, -65°C to +70°C, HT 7012 S2
Vötsch
Heraeus Schocktestkammer
固定価格 消費税別
€13,850
状態
中古
所在地
Borken 

基本データ
- メーカー:
- Vötsch
- 状態:
- 中古
価格と所在地
固定価格 消費税別
€13,850
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A22148082
- リファレンス番号:
- 23355
- 更新:
- 最終更新日:30.10.2026
説明
Heraeus
Type: HT 7012 S2
Temperature shock test chamber, water-cooled
Two-chamber design
Warm chamber:
Bodezd R Uwepfx Akcolp
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -80°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Type: HT 7012 S2
Temperature shock test chamber, water-cooled
Two-chamber design
Warm chamber:
Bodezd R Uwepfx Akcolp
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate:
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -80°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
お問い合わせを送信
電話 & ファックス
+49 2861 ... 広告
これらの広告もご興味があるかもしれません。
成功
あなたのメッセージが送信されました。
小型広告
Borken
9,154 km
ヘレウス ショックテストチャンバー HT 7012 S2 +50°C〜+220°Cおよび-65°C〜+70°C
VötschHeraeus Schocktestkammer 7012 S2
VötschHeraeus Schocktestkammer 7012 S2
あなたの掲載は正常に削除されました
エラーが発生しました