レーザー切断および溶接システムScanlab
PowerScan II 50i
レーザー切断および溶接システム
Scanlab
PowerScan II 50i
固定価格 消費税別
€2,800
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
固定価格 消費税別
€2,800
- 所在地:
- Einsteinstraße 8a, 46325 Borken, DE
電話する
オファーの詳細
- 広告ID:
- A20343425
- リファレンス番号:
- 24832
- 更新:
- 最終更新日:21.10.2025
説明
Scanlab PowerScanII 50i
Aperture: 50 mm
Angle Encoder: Galvanometer scanner with analog position detector
Optics Wavelength Range (Standard): 9400 nm, 10600 nm
Max. Laser Power: 2500 W at 9400 nm, 10600 nm
Typical Deflection Angle: ±0.35 rad (optical)
Dynamics Number of Installed Tunings: 1
Typical Tuning: Fast-Vector Tuning
Tracking Delay: < 0.45 ms
Positioning Speed (f = 160 mm): 20 rad/s
Step Response (100% Full Deflection):
1% Full Deflection: 1.0 ms
10% Full Deflection: 4.5 ms
Kedpfjxp Iybsx Afmsnc
Accuracy:
Repeatability (RMS): < 4 µrad
Max. Positioning Resolution: 18 Bit for XY, 16 Bit for Z*
Nonlinearity: < 2.1 mrad / 44°
8-hr Drift (after 30 min):
Offset: < 50 µrad
Gain: < 50 ppm
Electrical / Control
Control: Galvanometer scanner, digital controller card
Control Interface (alternatives): Digital SL2-100
Advanced Diagnostics: Yes (iDRIVE)
Power Supply: (48±2) V DC, max. 10 A each (20 A peak current)
Mechanical
Scan Axes: 3-axis system with integrated varioSCAN
Housing Variants: Scan head
Connector Positions: Opposite to beam exit
Weight without Lens (standard housing): 35 kg
Dimensions (L x W x H, standard housing): (433 x 268 x 266) mm (with varioSCAN)
Beam Offset: 72.72 mm
Other Features
Water cooling: Yes
Air cooling: Yes
Other Specifications
Operating Temperature: 25 °C ± 10 °C
Deflection Angle Deviation: < 5 mrad
Zero Position Deviation: < 5 mrad
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change. Information may contain errors!)
Shipping & Collection:
Secure pallet shipping (by arrangement) or local pickup possible.
For further questions, we will be happy to assist you by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Aperture: 50 mm
Angle Encoder: Galvanometer scanner with analog position detector
Optics Wavelength Range (Standard): 9400 nm, 10600 nm
Max. Laser Power: 2500 W at 9400 nm, 10600 nm
Typical Deflection Angle: ±0.35 rad (optical)
Dynamics Number of Installed Tunings: 1
Typical Tuning: Fast-Vector Tuning
Tracking Delay: < 0.45 ms
Positioning Speed (f = 160 mm): 20 rad/s
Step Response (100% Full Deflection):
1% Full Deflection: 1.0 ms
10% Full Deflection: 4.5 ms
Kedpfjxp Iybsx Afmsnc
Accuracy:
Repeatability (RMS): < 4 µrad
Max. Positioning Resolution: 18 Bit for XY, 16 Bit for Z*
Nonlinearity: < 2.1 mrad / 44°
8-hr Drift (after 30 min):
Offset: < 50 µrad
Gain: < 50 ppm
Electrical / Control
Control: Galvanometer scanner, digital controller card
Control Interface (alternatives): Digital SL2-100
Advanced Diagnostics: Yes (iDRIVE)
Power Supply: (48±2) V DC, max. 10 A each (20 A peak current)
Mechanical
Scan Axes: 3-axis system with integrated varioSCAN
Housing Variants: Scan head
Connector Positions: Opposite to beam exit
Weight without Lens (standard housing): 35 kg
Dimensions (L x W x H, standard housing): (433 x 268 x 266) mm (with varioSCAN)
Beam Offset: 72.72 mm
Other Features
Water cooling: Yes
Air cooling: Yes
Other Specifications
Operating Temperature: 25 °C ± 10 °C
Deflection Angle Deviation: < 5 mrad
Zero Position Deviation: < 5 mrad
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change. Information may contain errors!)
Shipping & Collection:
Secure pallet shipping (by arrangement) or local pickup possible.
For further questions, we will be happy to assist you by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
あなたの掲載は正常に削除されました
エラーが発生しました