ペイントショップ
Pony Luxury Coating Pony L11000 (11x5x5)

製造年
2025
状態
新しい
所在地
Würzburg ドイツ
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
ペイントショップ Pony Luxury Coating Pony L11000 (11x5x5)
more Images
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
Pony Luxury Coating Pony L11000 (11x5x5)
写真は示しています
地図を表示

機械に関するデータ

機械名:
ペイントショップ
メーカー:
Pony Luxury Coating
モデル:
Pony L11000 (11x5x5)
製造年:
2025
状態:
新しい
機能性:
完全に稼働しています

価格と所在地

所在地:
Schulstr 3, 97084 Würzburg, DE ドイツ
電話する

技術詳細

全高:
5,600 mm
全長:
11,200 mm
全幅:
5,100 mm
入力電流の種類:
三相
保証期間:
24 ヶ月
内寸高さ:
4,970 mm
内寸長:
11,000 mm
温度:
80 °C
内寸幅:
5,000 mm
空気需要:
52,000 m³/時
入力電圧:
380 V
暖房能力:
250 キロワット (339.91 馬力)
出力:
45 キロワット (61.18 馬力)
燃料:
液化石油ガス(LPG)
入力周波数:
50 ヘルツ
エネルギー消費量:
45 キロワット時
断熱材厚さ:
50 mm
定格出力:
250 キロワット (339.91 馬力)
鋼板厚さ(最大):
2 mm
装備:
照明

オファーの詳細

広告ID:
A19572531
更新:
最終更新日:07.10.2025

説明

* Air Preparation Unit:
The air preparation unit is a recirculation system that supplies the cabin with filtered fresh air and exhausts used air during the painting process. It heats the air to 60 °C, mixes the used air with 10% fresh air via an automatic multi-damper system, and reheats the air before routing it back into the cabin. The air is heated using a burner and a heat exchanger, both made of high-quality 304 stainless steel and housed within the fresh air unit. During painting, the air is filtered twice (via front and ceiling filters) before it enters the cabin. The contaminated air is also filtered twice (through inlet and outlet filters) before it exits via the exhaust unit. Air preparation units are insulated like the side walls to minimize heat loss and are protected against potential vibration and noise thanks to rubber seals on the covers. The exhaust air is regulated by a damper in the outlet duct, which helps control the internal pressure of the cabin.

* PRINCIPLES OF CABIN OPERATION:
The processes in the cabin are controlled via a control panel that manages the following steps:

* PAINTING PROCESS:
During painting, 100% fresh air is drawn in from outside and passed through front filters before entering the distribution chamber at ambient temperature. The air is then expelled by the extraction unit. Floor filters (paint stops) capture paint particles, and the air passes through the final exhaust filters before being discharged.

* FLASH-OFF PROCESS:
After painting, the cabin operates for approximately 15 more minutes to purge residual solvents and thinners. During this phase, fresh air from outside continues to circulate in the cabin.

* DRYING PROCESS:
In this phase, 80% of the air passing through the cabin is heated to 60 °C and supplied to the cabin via a distributor. As 20% of the solvent is released during drying, these solvents are expelled with the exhaust air. Industrial coatings are typically dried at 60 °C, but the cabin temperature can be adjusted via the control panel as required.

* COOLING PROCESS:
After the 30-minute drying process, the coil is deactivated via the control panel, the pneumatic damper closes, and the extraction system restarts. During the 5-minute cooling phase, fresh air from outside circulates in the cabin, after which the system stops automatically.

Bodpfx Aswzl Hxoduelp
ELECTRICAL AND ELECTRONIC EQUIPMENT:
These control panels manage the functions and operation of all machinery and devices inside the cabin. The control panel is constructed from durable galvanized sheet metal and steel profiles and is fully enclosed to protect against dust and moisture.
Electrical devices and control panels:
• The control panel contains essential components such as circuit breakers, fuses, indicator lamps, thermal relays, contactors, and connectors.
• Heat-resistant cables are used for command and control lines between the panel and motors or other electrical devices.
• Electrical wiring is designed to allow for cabin relocation if necessary.
• Operating devices use 380 V 50 Hz, while control devices use 220 V.

この広告は自動翻訳されています。翻訳ミスがある可能性があります。

提供者

最終オンライン:先週

登録日: 2025

10 オンライン広告

電話する

お問い合わせを送信

土地us 
ドイツ
オーストリア
スイス
アメリカ合衆国
イギリス
フランス
ベルギー
スペイン
メキシコ
イタリア
オランダ
ポーランド
ロシア連邦
ベラルーシ(ベラルーシ共和国)
ウクライナ
エストニア
トルコ
ニュージーランド
アイルランド
チェコ共和国
デンマーク
フィンランド
スウェーデン
ノルウェー
ルクセンブルク
ギリシャ
リトアニア
ラトビア
アイスランド
ポルトガル
ブラジル
ベネズエラ
アルゼンチン
ハンガリー
スロバキア
ルーマニア
モルドバ
スロベニア
セルビア
モンテネグロ
アルバニア
クロアチア
ブルガリア
北マケドニア
ボスニア・ヘルツェゴビナ
イスラエル
エジプト
モロッコ
インド
インドネシア
韓国
日本
タイ
マレーシア
ベトナム
China
台湾
イラン
バングラデシュ
アフガニスタン
注記: ご依頼は該当機械カテゴリの全販売業者に転送されます。 これにより、多くのオファーを受け取ることができます。
リクエストを送信できませんでした。後でもう一度お試しください。

電話 & ファックス

+49 176 7... 広告