Pacific Scientific 3313LL Met One パーティクルカウンターPacific Scientific
3313LL Met One
Pacific Scientific 3313LL Met One パーティクルカウンター
Pacific Scientific
3313LL Met One
状態
中古
所在地
Duxford 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Duxford, UK

電話する
オファーの詳細
- 広告ID:
- A20502585
- リファレンス番号:
- 23241.SR11B
- 更新:
- 最終更新日:11.11.2025
説明
This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
Tsdpfexv Ab Hsx Ag Aof
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
Tsdpfexv Ab Hsx Ag Aof
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
あなたの掲載は正常に削除されました