Pacific Scientific 3313LL Met One パーティクルカウンターPacific Scientific
3313LL Met One
Pacific Scientific 3313LL Met One パーティクルカウンター
Pacific Scientific
3313LL Met One
状態
中古
所在地
Duxford 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Duxford, UK

電話する
オファーの詳細
- 広告ID:
- A20502585
- リファレンス番号:
- 23241.SR11B
- 更新:
- 最終更新日:11.11.2025
説明
This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
Lhjdsxv Ab Hjpfx Agwob
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
Lhjdsxv Ab Hjpfx Agwob
これらの広告もご興味があるかもしれません。
小型広告
Borken
9,154 km
熱と乾燥キャビネット
HeraeusUT 6060 bis 300 °C
HeraeusUT 6060 bis 300 °C
小型広告
Borken
9,154 km
110リットルの温度キャビネット
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
小型広告
Freising
9,233 km
卓上型走査型電子顕微鏡
JEOLJCM-7000
JEOLJCM-7000
小型広告
Borken
9,154 km
温度庫 110リットル
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
小型広告
Duxford
9,398 km
Handilaz ミニパーティクルカウンター
HandilazMini
HandilazMini
小型広告
Duxford
9,398 km
LASAIR III 310c パーティクル計測システム
Particle Measuring SystemsLASAIR lll 310c
Particle Measuring SystemsLASAIR lll 310c
小型広告
Duxford
9,398 km
Pharmagraph S1816 パーティクルカウンター
PharmagraphS1816
PharmagraphS1816
あなたの掲載は正常に削除されました
エラーが発生しました






















































