未使用の10,000リットル加熱・冷却可能な圧力タンク(低温液体用、Aisi 304 製)
9162
未使用の10,000リットル加熱・冷却可能な圧力タンク(低温液体用、Aisi 304 製)
9162
EXW VB 消費税別
€15,500
製造年
2010
状態
中古
所在地
Bremen 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
EXW VB 消費税別
€15,500
- 所在地:
- Bremen
電話する
技術詳細
- タンク容量:
- 10,000 l
オファーの詳細
- 広告ID:
- A20350795
- リファレンス番号:
- 9162
- 更新:
- 最終更新日:22.10.2025
説明
Location: Bremen
Condition: unused
Volume: 10,000 liters
Max. excess pressure: 18.0 bar
Tank
Max. operating temperature (tank): 50°C
Design: vertical
Tank
Support type: feet
Number of feet: 3 pcs
Heating/Cooling: available
Heating/Cooling jacket
Internal temperature control: full-tube coil
Insulation: available
Insulation
Ljdpfxexqb Ino Afmsah
Insulation jacket: bolted
Insulation jacket material: stainless steel
External diameter: 1,850 mm
Cylindrical height: 5,239 mm
Overall height: 7,700 mm
Overall width: 2,300 mm
Year of manufacture: 2010
Technical documentation: drawing, various documents, operating manual
Nameplate:
Equipment
Note: light residues, pressure marks on the cylinder
Comments: Tank designed for LNG filling station but never put into operation; a tube bundle is installed inside through the flange, which can be used for temperature control; 2 transport cradles made of Fe are available; insulation and insulation jacket partially missing in the upper area of the cylinder;
Product contact material: V2A 1.4301 (AISI304)
Material properties
Foot material: steel
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Condition: unused
Volume: 10,000 liters
Max. excess pressure: 18.0 bar
Tank
Max. operating temperature (tank): 50°C
Design: vertical
Tank
Support type: feet
Number of feet: 3 pcs
Heating/Cooling: available
Heating/Cooling jacket
Internal temperature control: full-tube coil
Insulation: available
Insulation
Ljdpfxexqb Ino Afmsah
Insulation jacket: bolted
Insulation jacket material: stainless steel
External diameter: 1,850 mm
Cylindrical height: 5,239 mm
Overall height: 7,700 mm
Overall width: 2,300 mm
Year of manufacture: 2010
Technical documentation: drawing, various documents, operating manual
Nameplate:
Equipment
Note: light residues, pressure marks on the cylinder
Comments: Tank designed for LNG filling station but never put into operation; a tube bundle is installed inside through the flange, which can be used for temperature control; 2 transport cradles made of Fe are available; insulation and insulation jacket partially missing in the upper area of the cylinder;
Product contact material: V2A 1.4301 (AISI304)
Material properties
Foot material: steel