炭素-硫黄分析Leco
C 230 Anorganische Elementaranalytik
炭素-硫黄分析
Leco
C 230 Anorganische Elementaranalytik
固定価格 消費税別
€5,700
状態
中古
所在地
Borken 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
固定価格 消費税別
€5,700
- 所在地:
- Einsteinstraße 8a, 46325 Borken, Deutschland

電話する
オファーの詳細
- 広告ID:
- A20546160
- リファレンス番号:
- 24420
- 更新:
- 最終更新日:17.11.2025
説明
Leco
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Ledpfx Asxxaxuebnoai
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Ledpfx Asxxaxuebnoai
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
これらの広告もご興味があるかもしれません。
小型広告
Borken
9,154 km
走査型電子顕微鏡
ZeissEVO 50 inkl. EDS Ultim Max 100
ZeissEVO 50 inkl. EDS Ultim Max 100
小型広告
Mainz
9,261 km
走査型電子顕微鏡 (SEM)
ZeissXB 350
ZeissXB 350
小型広告
Köln
9,232 km
クリーンエアワークベンチ
HeraguardHPH 15
HeraguardHPH 15
小型広告
ドイツ
14,139 km
フィルターシステム - 浸透システム
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
小型広告
Borken
9,154 km
ハイエンド元素分析装置
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
小型広告
Borken
9,154 km
湿度調整機能付き恒温槽 34リットル
WeissWKL 34/40 -40...+150°C
WeissWKL 34/40 -40...+150°C
小型広告
Töltéstava
8,992 km
GC(オートサンプラー、FID、PC&ソフトウェア付き)
Agilent6890N
Agilent6890N
小型広告
Freising
9,233 km
断面研磨機
JEOLIB-19530CP
JEOLIB-19530CP
小型広告
Borken
9,154 km
塩水噴霧腐食試験キャビネット
VLMSAL 1000-FL PLC / V.715.362.520
VLMSAL 1000-FL PLC / V.715.362.520
小型広告
Borken
9,154 km
システムトレース質量分析計
Thermo FinniganMS 2160 mit Finnigan DSQ II
Thermo FinniganMS 2160 mit Finnigan DSQ II
あなたの掲載は正常に削除されました
エラーが発生しました









































































































