計測システムHexagon
ROMER Absolute ARM RA-7525-4
計測システム
Hexagon
ROMER Absolute ARM RA-7525-4
製造年
2014
状態
中古
所在地
Balaguer 

機械に関するデータ
価格と所在地
- 所在地:
- Calle mestral, 8, 25600 Balaguer, España

電話する
技術詳細
- 入力電圧:
- 15 V
- 動作温度:
- 50 °C
- 入力電流:
- 3 A
- 繰返し精度:
- 0.02 mm
オファーの詳細
- 広告ID:
- A22796665
- 更新:
- 最終更新日:22.09.2026
説明
Brand: Hexagon Metrology (ROMER line), manufactured in Montoire, France.
Model: ROMER Absolute Arm, Type RA-7525-4.
Serial number: 7525-2336-FA.
Date of manufacture: 09/04/2014
Configuration: 6 axes, contact probe (does not include an integrated laser scanning head, only a ball probe).
Measurement range (working volume): 2.5 m in diameter.
Point repeatability: ±0.020 mm.
Knjdpsz D An Hjfx Afnjb
Volumetric accuracy: ±0.029 mm.
Approximate arm weight: ~8 kg.
Operating temperature: 0 °C – 50 °C.
Power supply: 15 V DC, 3.0 A.
Mobility accessory: battery/pack "FP2 Mobility Pack" (Hexagon Metrology SAS, ID FP2-2423-FA, manufactured 10/29/2014), which allows the arm to operate wirelessly.
Mounting: base with clamp/vise for table mounting, with the possibility of rotation.
Probes (styli): 2 interchangeable units, serialized to this arm (7525-2336-FA) — one with a pink ruby ball and the other with a larger diameter steel ball — stored in a rigid Hexagon case with space for a third probe and replacement keys.
Included computer equipment: HP ZBook laptop with metrology software loaded (in Spanish).
Calibration: ENAC certificate no. 0328/2018, ENAC accreditation 116/LC10.083, calibration date 07/27/2018.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Model: ROMER Absolute Arm, Type RA-7525-4.
Serial number: 7525-2336-FA.
Date of manufacture: 09/04/2014
Configuration: 6 axes, contact probe (does not include an integrated laser scanning head, only a ball probe).
Measurement range (working volume): 2.5 m in diameter.
Point repeatability: ±0.020 mm.
Knjdpsz D An Hjfx Afnjb
Volumetric accuracy: ±0.029 mm.
Approximate arm weight: ~8 kg.
Operating temperature: 0 °C – 50 °C.
Power supply: 15 V DC, 3.0 A.
Mobility accessory: battery/pack "FP2 Mobility Pack" (Hexagon Metrology SAS, ID FP2-2423-FA, manufactured 10/29/2014), which allows the arm to operate wirelessly.
Mounting: base with clamp/vise for table mounting, with the possibility of rotation.
Probes (styli): 2 interchangeable units, serialized to this arm (7525-2336-FA) — one with a pink ruby ball and the other with a larger diameter steel ball — stored in a rigid Hexagon case with space for a third probe and replacement keys.
Included computer equipment: HP ZBook laptop with metrology software loaded (in Spanish).
Calibration: ENAC certificate no. 0328/2018, ENAC accreditation 116/LC10.083, calibration date 07/27/2018.