Hach DR 3800 VIS Spectrophotometer
The DR 3800 is a VIS spectrophotometer with a wavelength range from 320 to 1100 nm. The instrument comes with a complete set of application programs and supports multiple languages. The DR 3800 spectrophotometer includes the following
Programs and operating modes:
Stored Programs (pre-installed tests), Barcode Programs, User Programs, Favorites, Single Wavelength, Multi-Wavelength, Wavelength Scan, and Time Scan.
The DR 3800 Spectrophotometer performs digital measurements in units of concentration, absorbance, or % transmittance.
When a user-generated or programmed procedure is selected, a structured menu system and prompts guide the user through the test. This menu system can also generate reports, statistical evaluations of generated calibration curves, and reports on instrument diagnostic tests.
Display modes: transmittance (%), absorbance, and concentration
Light source: Halogen lamp
Wavelength range: 320-1100 nm
Wavelength accuracy: ± 1.5 nm (wavelength range 340-900 nm)
Wavelength reproducibility: 0.1 nm
Wavelength resolution: 1 nm
Wavelength calibration: automatic
Wavelength selection: automatic, depending on selected method
Scanning speed: = 12 nm/s (in 1 nm steps)
Spectral bandwidth: 5 nm
Photometric measuring range: ± 3.0 Ext (wavelength range 340-900 nm)
Photometric accuracy: 5 mExt at 0.0-0.5 Ext; 1 % at 0.50-2.0 Ext
Stray light: < 0.1 % T at 340 nm with NaNO2
Data memory: 1000 measured values (result, date, time, sample ID, user ID)
User programs: 50
Meter dimensions and environmental conditions: Width 368 mm; height 144 mm; depth 359 mm; weight 6.4 kg
Ambient conditions (operation): 10-40 °C, max. 80 % relative humidity (without condensation)
Ambient conditions (storage): -40-60 °C, max. 80 % relative humidity (without condensation)
External power supply: 100-240 V/50-60 Hz (input); 15 V/30 VA (output)
Interfaces: Use only shielded cables with max. 3 m length. 1 x USB type A; 1 x USB type B
Housing protection class: IP3X
Circuit classification: Device: Class III; System: Class II
Item condition: used
Todpfx Ajiuzvxsh Ijf
More items - new and used - you can find in our store!
International shipping costs on request!
The DR 3800 is a VIS spectrophotometer with a wavelength range from 320 to 1100 nm. The instrument comes with a complete set of application programs and supports multiple languages. The DR 3800 spectrophotometer includes the following
Programs and operating modes:
Stored Programs (pre-installed tests), Barcode Programs, User Programs, Favorites, Single Wavelength, Multi-Wavelength, Wavelength Scan, and Time Scan.
The DR 3800 Spectrophotometer performs digital measurements in units of concentration, absorbance, or % transmittance.
When a user-generated or programmed procedure is selected, a structured menu system and prompts guide the user through the test. This menu system can also generate reports, statistical evaluations of generated calibration curves, and reports on instrument diagnostic tests.
Display modes: transmittance (%), absorbance, and concentration
Light source: Halogen lamp
Wavelength range: 320-1100 nm
Wavelength accuracy: ± 1.5 nm (wavelength range 340-900 nm)
Wavelength reproducibility: 0.1 nm
Wavelength resolution: 1 nm
Wavelength calibration: automatic
Wavelength selection: automatic, depending on selected method
Scanning speed: = 12 nm/s (in 1 nm steps)
Spectral bandwidth: 5 nm
Photometric measuring range: ± 3.0 Ext (wavelength range 340-900 nm)
Photometric accuracy: 5 mExt at 0.0-0.5 Ext; 1 % at 0.50-2.0 Ext
Stray light: < 0.1 % T at 340 nm with NaNO2
Data memory: 1000 measured values (result, date, time, sample ID, user ID)
User programs: 50
Meter dimensions and environmental conditions: Width 368 mm; height 144 mm; depth 359 mm; weight 6.4 kg
Ambient conditions (operation): 10-40 °C, max. 80 % relative humidity (without condensation)
Ambient conditions (storage): -40-60 °C, max. 80 % relative humidity (without condensation)
External power supply: 100-240 V/50-60 Hz (input); 15 V/30 VA (output)
Interfaces: Use only shielded cables with max. 3 m length. 1 x USB type A; 1 x USB type B
Housing protection class: IP3X
Circuit classification: Device: Class III; System: Class II
Item condition: used
Todpfx Ajiuzvxsh Ijf
More items - new and used - you can find in our store!
International shipping costs on request!
これらの広告もご興味があるかもしれません。
小型広告
Bitburg
9,337 km
ブリケッティングプレス
WEIMAC 140 - sofort verfügbar - Vorführgerät
WEIMAC 140 - sofort verfügbar - Vorführgerät
小型広告
Griechenland
9,421 km
油圧ポンプ
BRUENINGHAUS30kw 280BAR
BRUENINGHAUS30kw 280BAR
小型広告
Dinkelscherben
9,295 km
マグネットプレート ウッドチップ
die magnetprofisPEM420x250x100
die magnetprofisPEM420x250x100
小型広告
Borken
9,154 km
走査型電子顕微鏡(PC-SEM)
JeolJSM-6490 Bruker XFlash Detektor
JeolJSM-6490 Bruker XFlash Detektor
小型広告
Dinkelscherben
9,295 km
オーバーバンドマグネット 磁性板 ブロックマグネット
die magnetprofisPEM620x420x200
die magnetprofisPEM620x420x200
小型広告
アイルランド
9,582 km
ツインリボンミキサー
Twin Ribbon Mixer
Twin Ribbon Mixer
小型広告
Gladbeck
9,175 km
排水システム デカンター移動式
HillerDP51 mobil
HillerDP51 mobil
小型広告
Ursberg
9,305 km
じどうじきろかシステム
die magnetprofisAPMA400
die magnetprofisAPMA400
小型広告
Radeberg
8,901 km
ステンレス製遠心ポンプ 化学標準ポンプ
Sulzer 75kW ; 250m³/h ; 27mZA200-450
Sulzer 75kW ; 250m³/h ; 27mZA200-450
小型広告
Petrovče
9,236 km
シュレッダー
Robust¸Reuser SD 700/22 kW
Robust¸Reuser SD 700/22 kW
あなたの掲載は正常に削除されました
エラーが発生しました