Used plant
Year of manufacture: 2023
Condition: Like new, the plant was never put into production operation
Equipment and technical data:
Stationary clean air filter unit ECO JET DUO 6 XL ZRS 2 x 7.5 kW
For extraction of wood dust and wood chips
- Fans: 2 x 7.5 kW
- Air volume flow: 10,000 m³/h
- Negative pressure: 2,700 Pa (total) / 2,200 Pa (static)
- Filters: 80 units of 2.50 m each
- BIA Category M, electrically conductive
- Filter area: 77.6 m²
- Filter surface load: 129 m³/(m²xh)
- Filter cleaning: AL-KO OPTI JET®
- Pressure relief surfaces: 0.84 m² (bursting discs)
- Base frame with discharge chute and rotary valve
Dry discharge with C-coupling
Consisting of:
- ECO JET DUO 6 UPPER SECTION, 2 x 7.5 KW:
Clean air filter unit;
2 x 7.5 kW fans;
AL-KO OPTI-JET filter cleaning;
Including pressure relief surfaces and
Dry discharge with C-coupling;
Without filters and control system;
Including pressure switches
- ECO JET DUO 6 ZWR XL - 1100 MM:
Spacer ring for increased expansion
or unit height
With 2 connection openings for intake nozzles
- Base frame with discharge chute
and integrated rotary valve
960/1 FG:
For removal of chips via on-site
transport fan into existing silo or similar
Transport pipe DN 200 mm, approx. 1,260 mm
long underneath the rotary valve, connection
to transport pipe by customer
Rotary valve certified according to ATEX Directive 94/9/EC
Technical data ZRS 960/1FG:
CE 0588 Ex II 1D/- (indoor/outdoor device);
EX D (protection system); FSA 11 ATEX 1614X
Motor power:
0.18 kW / 0.78 A
3 Ph / 400 V / 50 Hz
Protection type/Design:
IP 54 / B3
Insulation class: F
Speed:
41 rpm
Throughput*:
15,744 l/h*
Number of cells:
7
Inlet/Outlet cross-section:
960 x 250 mm /
960 x 208 mm
Dimensions (WxDxH):
Kwsdpsyk I U Asfx Agwou
1,100 x 605 x 330 mm
Temperature range:
up to 50°C
*depending on material
- FILTER & SUPPORT CAGE 2.5 / CAT M EL WHITE
FILTER ECO JET DUO 6:
80 units required
Filter BIA Category 'M' – electrically conductive;
2.50 m length, including support cages;
77.6 m² filter area
- Intake nozzle 400 mm:
with non-return damper in rectangular duct
- ECO JET backflow damper
910x346x500
- Control cabinet – AL-KO Control System:
BASIC CONTROL ACS II WITH TOUCHSCREEN DISPLAY:
Base unit for cascade control of 2 fans via frequency inverter (FU) up to max. 37 kW; corresponding power section and controls as well as the frequency inverter are included in the base unit; the frequency inverter is installed in the control cabinet
Cascade operation with FU changeover:
Fan 1 runs via the frequency inverter (FU); when threshold reached, switch to mains operation;
Fan 2 takes over the FU and control as needed;
Basic functions:
Control voltage 24 V
Touchscreen display, ST 1200 control,
Sitop Power power supply, Collective fault monitoring
Display of fault messages in plain text on the display and collective fault lamp in the door
Manual discharge start via display button
Start filter cleaning via differential pressure
Manual start of filter cleaning via button
Post-cleaning supervision
Brand monitoring...
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
Year of manufacture: 2023
Condition: Like new, the plant was never put into production operation
Equipment and technical data:
Stationary clean air filter unit ECO JET DUO 6 XL ZRS 2 x 7.5 kW
For extraction of wood dust and wood chips
- Fans: 2 x 7.5 kW
- Air volume flow: 10,000 m³/h
- Negative pressure: 2,700 Pa (total) / 2,200 Pa (static)
- Filters: 80 units of 2.50 m each
- BIA Category M, electrically conductive
- Filter area: 77.6 m²
- Filter surface load: 129 m³/(m²xh)
- Filter cleaning: AL-KO OPTI JET®
- Pressure relief surfaces: 0.84 m² (bursting discs)
- Base frame with discharge chute and rotary valve
Dry discharge with C-coupling
Consisting of:
- ECO JET DUO 6 UPPER SECTION, 2 x 7.5 KW:
Clean air filter unit;
2 x 7.5 kW fans;
AL-KO OPTI-JET filter cleaning;
Including pressure relief surfaces and
Dry discharge with C-coupling;
Without filters and control system;
Including pressure switches
- ECO JET DUO 6 ZWR XL - 1100 MM:
Spacer ring for increased expansion
or unit height
With 2 connection openings for intake nozzles
- Base frame with discharge chute
and integrated rotary valve
960/1 FG:
For removal of chips via on-site
transport fan into existing silo or similar
Transport pipe DN 200 mm, approx. 1,260 mm
long underneath the rotary valve, connection
to transport pipe by customer
Rotary valve certified according to ATEX Directive 94/9/EC
Technical data ZRS 960/1FG:
CE 0588 Ex II 1D/- (indoor/outdoor device);
EX D (protection system); FSA 11 ATEX 1614X
Motor power:
0.18 kW / 0.78 A
3 Ph / 400 V / 50 Hz
Protection type/Design:
IP 54 / B3
Insulation class: F
Speed:
41 rpm
Throughput*:
15,744 l/h*
Number of cells:
7
Inlet/Outlet cross-section:
960 x 250 mm /
960 x 208 mm
Dimensions (WxDxH):
Kwsdpsyk I U Asfx Agwou
1,100 x 605 x 330 mm
Temperature range:
up to 50°C
*depending on material
- FILTER & SUPPORT CAGE 2.5 / CAT M EL WHITE
FILTER ECO JET DUO 6:
80 units required
Filter BIA Category 'M' – electrically conductive;
2.50 m length, including support cages;
77.6 m² filter area
- Intake nozzle 400 mm:
with non-return damper in rectangular duct
- ECO JET backflow damper
910x346x500
- Control cabinet – AL-KO Control System:
BASIC CONTROL ACS II WITH TOUCHSCREEN DISPLAY:
Base unit for cascade control of 2 fans via frequency inverter (FU) up to max. 37 kW; corresponding power section and controls as well as the frequency inverter are included in the base unit; the frequency inverter is installed in the control cabinet
Cascade operation with FU changeover:
Fan 1 runs via the frequency inverter (FU); when threshold reached, switch to mains operation;
Fan 2 takes over the FU and control as needed;
Basic functions:
Control voltage 24 V
Touchscreen display, ST 1200 control,
Sitop Power power supply, Collective fault monitoring
Display of fault messages in plain text on the display and collective fault lamp in the door
Manual discharge start via display button
Start filter cleaning via differential pressure
Manual start of filter cleaning via button
Post-cleaning supervision
Brand monitoring...
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
これらの広告もご興味があるかもしれません。
小型広告
Voerde (Niederrhein)
9,184 km
スクリューコンベア、9.4m
AskaniaTSF315
AskaniaTSF315
小型広告
Nattheim
9,278 km
プレスによる抽出システム
Höcker Polytechnik
Höcker Polytechnik
小型広告
Jonava
8,097 km
20-33-543 集塵機
WOODLAND MACHINERYDC-9052
WOODLAND MACHINERYDC-9052
小型広告
Berlin
8,819 km
チップの取り出し
Höcker PolytechnikK 40/400
Höcker PolytechnikK 40/400
小型広告
Jonava
8,097 km
20-33-537 集塵機
WOODLAND MACHINERYDC9030
WOODLAND MACHINERYDC9030
小型広告
Gorzów Wielkopolski
8,707 km
固定式抽出システム 4500 m3h
HolzingRLA 125 VIBER Power 4500 m3h
HolzingRLA 125 VIBER Power 4500 m3h
小型広告
Siedlce
8,409 km
おがくず抽出
CORMAKFM500
CORMAKFM500
小型広告
Gronau (Westfalen)
9,115 km
定置排気システム
SchukoS 300/0/L2
SchukoS 300/0/L2
小型広告
Gerolzhofen
9,171 km
カンナナイフ研磨機
ISELIFL/T 400 V
ISELIFL/T 400 V
あなたの掲載は正常に削除されました
エラーが発生しました