説明
This listing is for 1 of 7 Watson Marlow 620S/R Peristaltic Pumps
The units are in full working condition and ready for immediate use
Design & Functionality
The 620S/R model is part of the 600 Series of cased peristaltic pumps featuring a brushless DC motor equipped with digital keypad control (620S) and a sturdy NEMA 2 / IP31 vented, wipe‑down enclosure suited for dry industrial environments ,It operates at dual voltage (100–120 V or 200–240 V, 50/60 Hz) and includes features like MemoDose for one-shot dosing and wireless guard-switching for safety
The casing is chemically resistant, with powder-coated die-cast aluminium construction and an easy-to-clean membrane keypad
Pump Performance
Flow range: 0.00026 to ~4.23 gpm (equivalent to ~0.001 to 16 L/min) with the 620R pump head
With newer 620RE LoadSure heads, the flow increases up to ~4.76 gpm (0.004–18 L/min)
Pressure capability: Up to approximately 60 psi (4 bar) with the appropriate head and tubing
Control accuracy: Exceptional 2,650:1 turndown ratio, fine speed control from 0.1 to 265 rpm in selectable increments (0.1, 0.5, 1, 2, 5, or 10 rpm), with 0.1% speed accuracy
Pump Heads & Tubing
The model supports the following interchangeable pump heads:
620R Mk II (continuous tubing, two rollers)
620RE and 620RE4 (LoadSure elements, two or four rollers)
These heads are compatible with various tubing materials (e.g., Marprene™, Bioprene™, Sta‑Pure™, silicone) and sizes (typically 6.4 mm to 17 mm inner diameter)
The 620RE and RE4 heads feature retractable rollers for easier cleaning (CIP/SIP) and rapid loading
AFAB Lab Resources - Used Lab Equipment
Physical Attributes & Construction
Ingress Protection: IP31 (NEMA 2) for the standard 620S/R; there are IP66/NEMA 4X variants (e.g., 620SN/R) for environments requiring better dust and water resistance
Weight: Around 19.6 kg (with 620R/RE head) to 20.1 kg (with 620RE4)
Sound level: Less than 70 dB(A) at 1 m—relatively quiet for continuous industrial operation
Advanced Features
MemoDose: Delivers precise single-shot volumes—ideal for dosing applications
Ramp function & non‑drip: Ramp improves handling of delicate fluids, preventing splashes/frothing, while non-drip minimizes residual drips at dose end (noted in related Di versions but often included in feature suites)
Psdpfx Aaoxhdx De Rsgn
Data export: Some models (e.g. 620S/RE) support RS‑232 export of batch records—important for GMP compliance
The units are in full working condition and ready for immediate use
Design & Functionality
The 620S/R model is part of the 600 Series of cased peristaltic pumps featuring a brushless DC motor equipped with digital keypad control (620S) and a sturdy NEMA 2 / IP31 vented, wipe‑down enclosure suited for dry industrial environments ,It operates at dual voltage (100–120 V or 200–240 V, 50/60 Hz) and includes features like MemoDose for one-shot dosing and wireless guard-switching for safety
The casing is chemically resistant, with powder-coated die-cast aluminium construction and an easy-to-clean membrane keypad
Pump Performance
Flow range: 0.00026 to ~4.23 gpm (equivalent to ~0.001 to 16 L/min) with the 620R pump head
With newer 620RE LoadSure heads, the flow increases up to ~4.76 gpm (0.004–18 L/min)
Pressure capability: Up to approximately 60 psi (4 bar) with the appropriate head and tubing
Control accuracy: Exceptional 2,650:1 turndown ratio, fine speed control from 0.1 to 265 rpm in selectable increments (0.1, 0.5, 1, 2, 5, or 10 rpm), with 0.1% speed accuracy
Pump Heads & Tubing
The model supports the following interchangeable pump heads:
620R Mk II (continuous tubing, two rollers)
620RE and 620RE4 (LoadSure elements, two or four rollers)
These heads are compatible with various tubing materials (e.g., Marprene™, Bioprene™, Sta‑Pure™, silicone) and sizes (typically 6.4 mm to 17 mm inner diameter)
The 620RE and RE4 heads feature retractable rollers for easier cleaning (CIP/SIP) and rapid loading
AFAB Lab Resources - Used Lab Equipment
Physical Attributes & Construction
Ingress Protection: IP31 (NEMA 2) for the standard 620S/R; there are IP66/NEMA 4X variants (e.g., 620SN/R) for environments requiring better dust and water resistance
Weight: Around 19.6 kg (with 620R/RE head) to 20.1 kg (with 620RE4)
Sound level: Less than 70 dB(A) at 1 m—relatively quiet for continuous industrial operation
Advanced Features
MemoDose: Delivers precise single-shot volumes—ideal for dosing applications
Ramp function & non‑drip: Ramp improves handling of delicate fluids, preventing splashes/frothing, while non-drip minimizes residual drips at dose end (noted in related Di versions but often included in feature suites)
Psdpfx Aaoxhdx De Rsgn
Data export: Some models (e.g. 620S/RE) support RS‑232 export of batch records—important for GMP compliance
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
登録日: 2019
811 オンライン広告
お問い合わせを送信
電話 & ファックス
+44 20 38... 広告
これらの広告もご興味があるかもしれません。
小型広告
Wien
9,017 km
計測システム
KEYENCEVL-770
KEYENCEVL-770
小型広告
Walkeringham
9,309 km
コンベクションオーブン
Moretti ForniF80E
Moretti ForniF80E
小型広告
Misterton
9,308 km
1000L ハイシアーミキシングベッセル
GreavesHigh shear mixing vessel
GreavesHigh shear mixing vessel
小型広告
Wymysłów
8,615 km
KEYENCE VLシリーズ 光学システム
KEYENCE VL Series 3D VL-370KEYENCE VL Series 3D VL-370
KEYENCE VL Series 3D VL-370KEYENCE VL Series 3D VL-370
小型広告
Misterton
9,308 km
ポンプ
Jabsco200
Jabsco200
小型広告
Duxford
9,398 km
ワトソンマーロウ 323 ペリスタルティックポンプ
Watson-Marlow323
Watson-Marlow323
小型広告
London
9,461 km
ワトソンマーロウ 620 DU/R ペリスタルティックポンプ
Watson-Marlow620 Du/R
Watson-Marlow620 Du/R
小型広告
Duxford
9,398 km
Watson Marlow 520Di ペリスタルティックポンプ(脚なし)
Watson-Marlow520Di
Watson-Marlow520Di
小型広告
Duxford
9,398 km
Watson Marlow 313DW ペリスタルティックポンプヘッド
Watson Marlow 313DW Peristaltic Pump Head313DW
Watson Marlow 313DW Peristaltic Pump Head313DW
小型広告
Duxford
9,398 km
ワトソン・マーロウ 530S ペリスタルティックポンプ
Watson-Marlow530S
Watson-Marlow530S
あなたの掲載は正常に削除されました
エラーが発生しました