The unit comes with rotor and accessories !!!
⚙️ Thermo Scientific Cytospin 4 — technical specs
🧪 Performance
Speed range: 200 – 2000 rpm
Max RCF: ~850 × g
Capacity: up to 12 specimens per run
Timer: 1 – 99 minutes
Program memory: up to 23 stored routines
📏 Physical & electrical
Dimensions (H × W × D):
~9.5 × 16 × 24.5 in (≈ 24 × 40.5 × 62 cm)
Weight: ~12 kg (26.5 lb)
Power supply: 100–240 V, 50/60 Hz
Power consumption: ~150 VA max
🧠 Control & programming
Digital keypad with programmable protocols
Acceleration control (multiple ramp settings)
Speed and time display windows
Standby mode for power saving
🔒 Safety & design
Auto-locking lid (won’t run unless locked)
Imbalance / overspeed / lid alarms
Sealed rotor head with viewing window
Spill-resistant internal design
Complies with IEC 61010 safety standard
🧬 Functional features
Produces thin-layer cell deposition on slides
Compatible with Cytospin 1–3 protocols
Supports disposable or reusable sample chambers
Designed for low-cellularity samples (e.g., CSF, urine)
Kledpfx Amjy D D Nkepsr
Good working condition. Please check out our other listings as well.
⚙️ Thermo Scientific Cytospin 4 — technical specs
🧪 Performance
Speed range: 200 – 2000 rpm
Max RCF: ~850 × g
Capacity: up to 12 specimens per run
Timer: 1 – 99 minutes
Program memory: up to 23 stored routines
📏 Physical & electrical
Dimensions (H × W × D):
~9.5 × 16 × 24.5 in (≈ 24 × 40.5 × 62 cm)
Weight: ~12 kg (26.5 lb)
Power supply: 100–240 V, 50/60 Hz
Power consumption: ~150 VA max
🧠 Control & programming
Digital keypad with programmable protocols
Acceleration control (multiple ramp settings)
Speed and time display windows
Standby mode for power saving
🔒 Safety & design
Auto-locking lid (won’t run unless locked)
Imbalance / overspeed / lid alarms
Sealed rotor head with viewing window
Spill-resistant internal design
Complies with IEC 61010 safety standard
🧬 Functional features
Produces thin-layer cell deposition on slides
Compatible with Cytospin 1–3 protocols
Supports disposable or reusable sample chambers
Designed for low-cellularity samples (e.g., CSF, urine)
Kledpfx Amjy D D Nkepsr