Little used 11.6 MW Condensing Steam Turbine Generator, TGM Kanis Turbinen GmbH, 2017
Reported to have less than 100 operating hours due to project cancellation. Includes turbine, synchronous generator, auxiliaries, and controls.
Turbine
Manufacturer: TGM Kanis Turbinen (Germany)
Type: CT32-54 Condensing Steam Turbine
Year: 2017
Live Steam Conditions: 43 bar @ 398 °C
Exhaust Conditions: 0.064 bar @ 38 °C
Power Output: Max continuous 11,615 kW
Speed: 7,200 rpm
Kjdpfsxvq Nrjx Afnsdw
Generator
Manufacturer: Elin Motoren
Type: HTM290E04, synchronous generator
Rating: 14,631 kVA
Voltage: 11,000 V
Current: 768 A
Frequency: 50 Hz
Enclosure: IP54
Weight: 30,600 kg
Year: 2017
Auxiliaries
Voith Turbo I/P Converter
Type: DSG-B07143
Supply voltage: +24 VDC
Input pressure: 8 bar
Output pressure: 2–5 bar
Sirocco Cooling System
Type: 2x16 KDL-E-50-2-1850-2-1.8
Motor power: 253 kW
Air flow: 29,664 m³/h (65/35 °C, 2x0.065 kPa)
Water flow: 2×25 m³/h (25/29 °C, 10 kPa)
Pressure: 10–15 bar
Controls
Turbine control system included.
Turbine was intended to be fed by boiler (not included in sale) with steam production capacity of 52570 kg/hour.
Reported to have less than 100 operating hours due to project cancellation. Includes turbine, synchronous generator, auxiliaries, and controls.
Turbine
Manufacturer: TGM Kanis Turbinen (Germany)
Type: CT32-54 Condensing Steam Turbine
Year: 2017
Live Steam Conditions: 43 bar @ 398 °C
Exhaust Conditions: 0.064 bar @ 38 °C
Power Output: Max continuous 11,615 kW
Speed: 7,200 rpm
Kjdpfsxvq Nrjx Afnsdw
Generator
Manufacturer: Elin Motoren
Type: HTM290E04, synchronous generator
Rating: 14,631 kVA
Voltage: 11,000 V
Current: 768 A
Frequency: 50 Hz
Enclosure: IP54
Weight: 30,600 kg
Year: 2017
Auxiliaries
Voith Turbo I/P Converter
Type: DSG-B07143
Supply voltage: +24 VDC
Input pressure: 8 bar
Output pressure: 2–5 bar
Sirocco Cooling System
Type: 2x16 KDL-E-50-2-1850-2-1.8
Motor power: 253 kW
Air flow: 29,664 m³/h (65/35 °C, 2x0.065 kPa)
Water flow: 2×25 m³/h (25/29 °C, 10 kPa)
Pressure: 10–15 bar
Controls
Turbine control system included.
Turbine was intended to be fed by boiler (not included in sale) with steam production capacity of 52570 kg/hour.