メカトロニクス RPU-2100R 試薬製造ユニット/試薬調製ユニットRR Mechatronics
RPU-2100R
メカトロニクス RPU-2100R 試薬製造ユニット/試薬調製ユニット
RR Mechatronics
RPU-2100R
VB 消費税別
€2,436
製造年
2014
状態
中古
所在地
Borken 

基本データ
価格と所在地
VB 消費税別
€2,436
- 所在地:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

電話する
オファーの詳細
- 広告ID:
- A21266162
- リファレンス番号:
- 60198
- 更新:
- 最終更新日:07.10.2026
説明
Mechatronics RPU-2100R Reagent Production Unit
The Mechatronics RPU-2100R is a reagent production unit used in hematology to optimize reagent logistics in laboratories.
The device is manufactured by RR Mechatronics and is often used in combination with hematology analyzers from Sysmex.
Purpose and Function
The RPU-2100R (Reagent Production Unit) is designed to automatically dilute concentrated reagents (such as Cellpack S Conc.) and produce large quantities of ready-to-use reagent on-site in the laboratory.
The RPU-2100R is a single unit, with all components located within a closed housing.
The housing features removable, epoxy-coated sheet metal covers.
All external connections, as well as the ON/OFF switch, are located on the rear of the unit.
All components that can be serviced or replaced by the user are accessible via the front door.
The carriage for the Cellpack concentrate (e.g., Cellpack®-S Conc.) can be optionally attached to three sides of the unit.
Performance Characteristics and Capacities
The RPU-2100R focuses on optimizing reagent management for high-throughput laboratories:
Reagent concentrates: Uses Cellpack S Conc. in 10L and 20L containers.
Throughput per concentrate:
With a 10L container, up to 8,250 blood counts per month can be performed without changing the reagent.
With a 20L container, up to 16,500 blood counts per month are possible.
Shelf life: The mixed reagent has a shelf life of 30 days after opening.
Manufacturer: RR Mechatronics
Model: RPU-2100R
Catalog number: NARP109010
External connections
Power supply, Euro plug
Ethernet/USB (only NARP109010) RJ45/USB-B
RS-232 (only NARP109000) 9 Pin SUB D connector
External connections (liquids)
Water connection: G ¾" inch thread
Reagent output connection (4x)
Push-in hose connection, outer diameter 6 mm
Waste connection (1x) hose sleeve, hose inner diameter 12 mm
Reagent concentrate Maximum size: 390 x 260 x 300 mm (W x D x H)
Reagent: SYSMEX Cellpack Concentrate
Reagent dispensing rate: 0.5 liters/minute, 6 minutes max.
(with full supply and overflow container and new pre-filter) 1 liter/minute, 2 minutes max.
Filtration Air filter, bacterial filter, pore size 0.2 µm
Liquid pre-filter, particle filter (sterilized), pore size 0.8+0.45 µm, self-venting
Liquid final filter, bacterial filter (sterilized), pore size 0.2 µm, self-venting
Godpfxoyk U Dws Aazsuh
System dimensions
Width: 500 mm
Height: 700 mm
Depth: 430 mm
Weight: approx. 50 kg
Water container volume: 2.5 liters
Supply container: 2.5 liters
Mixing container: 0.6 liters
Overflow container: 0.6 liters
Language selection available: de, en, es, fr, hu, it, nl, sk,
sv (expandable)
Voltage: 230 VAC (+/- 10%)
Frequency: 50-60 Hz
Year of manufacture: 2014
More items - new and used - can be found in our shop!
International shipping costs upon request!
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
The Mechatronics RPU-2100R is a reagent production unit used in hematology to optimize reagent logistics in laboratories.
The device is manufactured by RR Mechatronics and is often used in combination with hematology analyzers from Sysmex.
Purpose and Function
The RPU-2100R (Reagent Production Unit) is designed to automatically dilute concentrated reagents (such as Cellpack S Conc.) and produce large quantities of ready-to-use reagent on-site in the laboratory.
The RPU-2100R is a single unit, with all components located within a closed housing.
The housing features removable, epoxy-coated sheet metal covers.
All external connections, as well as the ON/OFF switch, are located on the rear of the unit.
All components that can be serviced or replaced by the user are accessible via the front door.
The carriage for the Cellpack concentrate (e.g., Cellpack®-S Conc.) can be optionally attached to three sides of the unit.
Performance Characteristics and Capacities
The RPU-2100R focuses on optimizing reagent management for high-throughput laboratories:
Reagent concentrates: Uses Cellpack S Conc. in 10L and 20L containers.
Throughput per concentrate:
With a 10L container, up to 8,250 blood counts per month can be performed without changing the reagent.
With a 20L container, up to 16,500 blood counts per month are possible.
Shelf life: The mixed reagent has a shelf life of 30 days after opening.
Manufacturer: RR Mechatronics
Model: RPU-2100R
Catalog number: NARP109010
External connections
Power supply, Euro plug
Ethernet/USB (only NARP109010) RJ45/USB-B
RS-232 (only NARP109000) 9 Pin SUB D connector
External connections (liquids)
Water connection: G ¾" inch thread
Reagent output connection (4x)
Push-in hose connection, outer diameter 6 mm
Waste connection (1x) hose sleeve, hose inner diameter 12 mm
Reagent concentrate Maximum size: 390 x 260 x 300 mm (W x D x H)
Reagent: SYSMEX Cellpack Concentrate
Reagent dispensing rate: 0.5 liters/minute, 6 minutes max.
(with full supply and overflow container and new pre-filter) 1 liter/minute, 2 minutes max.
Filtration Air filter, bacterial filter, pore size 0.2 µm
Liquid pre-filter, particle filter (sterilized), pore size 0.8+0.45 µm, self-venting
Liquid final filter, bacterial filter (sterilized), pore size 0.2 µm, self-venting
Godpfxoyk U Dws Aazsuh
System dimensions
Width: 500 mm
Height: 700 mm
Depth: 430 mm
Weight: approx. 50 kg
Water container volume: 2.5 liters
Supply container: 2.5 liters
Mixing container: 0.6 liters
Overflow container: 0.6 liters
Language selection available: de, en, es, fr, hu, it, nl, sk,
sv (expandable)
Voltage: 230 VAC (+/- 10%)
Frequency: 50-60 Hz
Year of manufacture: 2014
More items - new and used - can be found in our shop!
International shipping costs upon request!
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
登録日: 2008
536 オンライン広告
お問い合わせを送信
電話 & ファックス
+49 2862 ... 広告
これらの広告もご興味があるかもしれません。
成功
あなたのメッセージが送信されました。
小型広告
Gera
9,007 km
自動車用トレーラー
Saris255cm x 153cm 1,5t Rampen+kl. Frontwand
Saris255cm x 153cm 1,5t Rampen+kl. Frontwand
あなたの掲載は正常に削除されました
エラーが発生しました