MYRKOS DGA ガスクロマトグラフMorgan Schaffer
MYRKOS Portable DGA MicroGC
MYRKOS DGA ガスクロマトグラフ
Morgan Schaffer
MYRKOS Portable DGA MicroGC
EXW VB 消費税別
€35,000
製造年
2012
状態
中古
(完全に稼働しています)
所在地
Rzeszów 

基本データ
価格と所在地
EXW VB 消費税別
€35,000
- 所在地:
- Rzeszów, ポーランド

電話する
技術詳細
寸法と重量
総重量:
80 kg(キログラム)
全長:
800 mm
全幅:
400 mm
全高:
350 mm
オファーの詳細
- 広告ID:
- A23375425
- 更新:
- 最終更新日:24.11.2026
説明
# COMPLETE DGA KIT – 2 × MYRKOS GAS CHROMATOGRAPHS + LABORATORY EQUIPMENT
For sale is a complete set of professional equipment for analyzing gases dissolved in insulating oils using the DGA (Dissolved Gas Analysis) method.
The set includes 2 MYRKOS gas chromatographs, manufactured in Canada, along with additional equipment necessary for sample preparation, calibration, and performing diagnostic tests on transformer oils. One unit has undergone maintenance in Canada at MYRKOS.
The units have been serviced in Canada and are in very good technical condition, fully functional, tested, and ready for use.
THE SET INCLUDES:
- 2 × MYRKOS DGA gas chromatographs,
- laptop with PPMReport software installed (Polish language version),
- shaker (vortex mixer) for sample preparation,
- several glass sample vials for collecting and preparing oil samples,
- equipment for calibration and measurement control,
- additional accessories and equipment as shown in the photos.
TECHNICAL CONDITION
Both chromatographs are in very good technical condition:
- 1 has undergone maintenance in Canada,
- Both are fully functional and tested,
- Calibrated, performing complete measurements,
- Regularly warmed up – at least once a month for 12 hours.
The last documented test was performed on November 21, 2025. The results were compared with the second MYRKOS unit and verified in the laboratory.
It is possible to perform a test analysis of transformer oil on-site before purchase.
APPLICATION
MYRKOS DGA chromatographs are used to determine the concentration of gases dissolved in insulating oils. The analysis allows for the detection and diagnosis of developing faults in power transformers and other electrical equipment.
Nledpfxo Alnwbe Ai Sei
Application:
- power transformers,
- reactors and current transformers,
- other equipment containing insulating oils,
- analysis of gas taken from Buchholz relays.
TECHNICAL PARAMETERS
Number of gases analyzed: 9:
H₂, CH₄, C₂H₆, C₂H₄, C₂H₂, CO, CO₂, O₂, N₂.
Measurement ranges:
- H₂: 5–60,000 ppm
- Other gases: 1–60,000 ppm
- O₂: 60–100,000 ppm
- N₂: 500–100,000 ppm
The PPMReport software includes diagnostic tools, including the Duval triangle and Rogers ratios.
COMMERCIAL INFORMATION
For sale only as a complete set: 2 MYRKOS DGA chromatographs, laptop, software, and additional equipment.
Location: Rzeszów, Poland.
Possibility to view and test the entire set before purchase.
Possibility to purchase 1 unit of the device.
PRICE NEGOTIABLE
We invite you to contact us for detailed information, to discuss the terms of purchase, and to arrange a demonstration of the equipment.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
For sale is a complete set of professional equipment for analyzing gases dissolved in insulating oils using the DGA (Dissolved Gas Analysis) method.
The set includes 2 MYRKOS gas chromatographs, manufactured in Canada, along with additional equipment necessary for sample preparation, calibration, and performing diagnostic tests on transformer oils. One unit has undergone maintenance in Canada at MYRKOS.
The units have been serviced in Canada and are in very good technical condition, fully functional, tested, and ready for use.
THE SET INCLUDES:
- 2 × MYRKOS DGA gas chromatographs,
- laptop with PPMReport software installed (Polish language version),
- shaker (vortex mixer) for sample preparation,
- several glass sample vials for collecting and preparing oil samples,
- equipment for calibration and measurement control,
- additional accessories and equipment as shown in the photos.
TECHNICAL CONDITION
Both chromatographs are in very good technical condition:
- 1 has undergone maintenance in Canada,
- Both are fully functional and tested,
- Calibrated, performing complete measurements,
- Regularly warmed up – at least once a month for 12 hours.
The last documented test was performed on November 21, 2025. The results were compared with the second MYRKOS unit and verified in the laboratory.
It is possible to perform a test analysis of transformer oil on-site before purchase.
APPLICATION
MYRKOS DGA chromatographs are used to determine the concentration of gases dissolved in insulating oils. The analysis allows for the detection and diagnosis of developing faults in power transformers and other electrical equipment.
Nledpfxo Alnwbe Ai Sei
Application:
- power transformers,
- reactors and current transformers,
- other equipment containing insulating oils,
- analysis of gas taken from Buchholz relays.
TECHNICAL PARAMETERS
Number of gases analyzed: 9:
H₂, CH₄, C₂H₆, C₂H₄, C₂H₂, CO, CO₂, O₂, N₂.
Measurement ranges:
- H₂: 5–60,000 ppm
- Other gases: 1–60,000 ppm
- O₂: 60–100,000 ppm
- N₂: 500–100,000 ppm
The PPMReport software includes diagnostic tools, including the Duval triangle and Rogers ratios.
COMMERCIAL INFORMATION
For sale only as a complete set: 2 MYRKOS DGA chromatographs, laptop, software, and additional equipment.
Location: Rzeszów, Poland.
Possibility to view and test the entire set before purchase.
Possibility to purchase 1 unit of the device.
PRICE NEGOTIABLE
We invite you to contact us for detailed information, to discuss the terms of purchase, and to arrange a demonstration of the equipment.
この広告は自動翻訳されています。翻訳ミスがある可能性があります。
提供者
注意: 無料で登録するかログインして、すべての情報を取得してください。
最終オンライン:先週
登録日: 2025
3 オンライン広告
お問い合わせを送信
電話 & ファックス
+48 607 6... 広告
あなたの掲載は正常に削除されました
エラーが発生しました























