Hitech Instruments GIR250 ガスアナライザーHitech Instruments
GIR250
Hitech Instruments GIR250 ガスアナライザー
Hitech Instruments
GIR250
状態
中古
所在地
Duxford 

写真は示しています
地図を表示
機械に関するデータ
価格と所在地
- 所在地:
- Duxford, UK
電話する
オファーの詳細
- 広告ID:
- A20123055
- リファレンス番号:
- 240850/7B
- 更新:
- 最終更新日:02.10.2025
説明
This listing is for the Hitech Instruments GIR250 Gas Analyser
The unit is in full working condition and is ready for immediate use
The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.
It is made by Hitech Instruments (now part of the MTL / Eaton group).
Its design emphasizes ease of use, reliability, and low maintenance cost.
Other supporting features:
The instrument can be programmed with pass/fail criteria for each gas (alarms).
It provides analog outputs, typically 4–20 mA, for external logging or control systems.
Calibration is designed to be simple (via the front panel keypad) to reduce training burden.
The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).
Mechanical, Electrical & Operational Details
The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.
Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.
The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.
Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)
Ijdpfxjxhdqto Afmetn
Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)
Typical Applications & Suitability
Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:
Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)
Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)
Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)
It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis
The unit is in full working condition and is ready for immediate use
The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.
It is made by Hitech Instruments (now part of the MTL / Eaton group).
Its design emphasizes ease of use, reliability, and low maintenance cost.
Other supporting features:
The instrument can be programmed with pass/fail criteria for each gas (alarms).
It provides analog outputs, typically 4–20 mA, for external logging or control systems.
Calibration is designed to be simple (via the front panel keypad) to reduce training burden.
The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).
Mechanical, Electrical & Operational Details
The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.
Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.
The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.
Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)
Ijdpfxjxhdqto Afmetn
Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)
Typical Applications & Suitability
Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:
Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)
Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)
Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)
It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis