Hitech Instruments GIR250 ガスアナライザー
Hitech Instruments GIR250

状態
中古
所在地
Duxford イギリス
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
Hitech Instruments GIR250 ガスアナライザー Hitech Instruments GIR250
more Images
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
写真は示しています
地図を表示

機械に関するデータ

価格と所在地

所在地:
Duxford, UK イギリス
電話する

オファーの詳細

広告ID:
A20123055
リファレンス番号:
240850/7B
更新:
最終更新日:02.10.2025

説明

This listing is for the Hitech Instruments GIR250 Gas Analyser

The unit is in full working condition and is ready for immediate use

The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.

It is made by Hitech Instruments (now part of the MTL / Eaton group).

Its design emphasizes ease of use, reliability, and low maintenance cost.

Other supporting features:

The instrument can be programmed with pass/fail criteria for each gas (alarms).

It provides analog outputs, typically 4–20 mA, for external logging or control systems.

Calibration is designed to be simple (via the front panel keypad) to reduce training burden.

The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).

Mechanical, Electrical & Operational Details

The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.

Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.

The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.

Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)
Ijdpfxjxhdqto Afmetn

Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)

Typical Applications & Suitability

Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:

Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)

Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)

Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)

It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis

提供者

電話する

お問い合わせを送信

土地us 
ドイツ
オーストリア
スイス
アメリカ合衆国
イギリス
フランス
ベルギー
スペイン
メキシコ
イタリア
オランダ
ポーランド
ロシア連邦
ベラルーシ(ベラルーシ共和国)
ウクライナ
エストニア
トルコ
ニュージーランド
アイルランド
チェコ共和国
デンマーク
フィンランド
スウェーデン
ノルウェー
ルクセンブルク
ギリシャ
リトアニア
ラトビア
アイスランド
ポルトガル
ブラジル
ベネズエラ
アルゼンチン
ハンガリー
スロバキア
ルーマニア
モルドバ
スロベニア
セルビア
モンテネグロ
アルバニア
クロアチア
ブルガリア
北マケドニア
ボスニア・ヘルツェゴビナ
イスラエル
エジプト
モロッコ
インド
インドネシア
韓国
日本
タイ
マレーシア
ベトナム
China
台湾
イラン
バングラデシュ
アフガニスタン
注記: ご依頼は該当機械カテゴリの全販売業者に転送されます。 これにより、多くのオファーを受け取ることができます。
リクエストを送信できませんでした。後でもう一度お試しください。

電話 & ファックス

+44 20 38... 広告